Imaging Equipment | National Institute of Environmental Health Sciences

Imaging Equipment | National Institute of Environmental Health Sciences
Skip Navigation
Imaging Equipment
Close the left navigation
Add
Fluorescence Microscopy and Imaging Center
Table of Contents
Zeiss LSM 980 inverted confocal microscope with AiryScan
Zeiss LSM 880 inverted confocal microscope with AiryScan
Zeiss LSM 780 inverted confocal microscope
Zeiss LSM 710 inverted confocal microscope
Zeiss Lightsheet 7
Andor Dragonfly Spinning Disk Confocal
Zeiss Colibri LED inverted epifluorescent microscope
Automated inverted epifluorescent microscope
Inverted epifluorescent microscope
Zeiss LSM 980 inverted confocal microscope with AiryScan
AiryScan2 Super Resolution & LSM plus
AI sample finder for quick tile scan set up
Laser Lines: 405, 445, 488, 514, 561, 594, 639, 730
Long term time-lapse: Incubation with variable CO2
Near IR excitation 730nm with emission out to 900nm
User Guide for Zeiss LSM 980 inverted confocal microscope with AiryScan
User Guide for Zeiss LSM 980 inverted confocal microscope with AiryScan
(4MB)
Zeiss LSM 880 inverted confocal microscope with AiryScan
AiryScan Super Resolution
Fluorescence Correlation Spectroscopy
Laser Lines: 405, 458, 488, 514, 561, 594, 633
Long term time-lapse: Incubation with variable CO2
Zeiss LSM 880 inverted confocal microscope with AiryScan User Guide
(601KB)
Zeiss LSM 780 inverted confocal microscope
355nm Laser for DNA Breaks
Short term time-lapse: Stage incubator with 5% CO2
Laser Lines: 355, 405, 458, 488, 514, 561, 594, 633
Zeiss LSM 780 inverted confocal microscope
(702KB)
Zeiss LSM 710 inverted confocal microscope
Multi-Photon laser
Incubation Chamber with 5% CO2
Laser Lines: 405, 458, 488, 514, 561, 633
Zeiss LSM 710 inverted confocal microscope
(614KB)
Zeiss Lightsheet 7
Image Optically Cleared Specimens up to 2cm
Temperature and CO2 incubation for live specimens
Dual side illumination with pivot scan
Dual sCMOS cameras
405nm, 445nm, 488nm, 515nm, 561nm, and 638nm laser excitation
Andor Dragonfly Spinning Disk Confocal
dSTORM capability
Dual Cameras (EMCCD and sCMOS) with fast acquisition times
Full incubation with CO2
TIRF Microscopy
Zeiss Colibri LED inverted epifluorescent microscope
Fast (100fps) 4megapixel sCMOS camera
7 color LED fluorescence excitation
Tile Scan
Objectives: 5X, 10X, 20X, 40X, 63X Oil
Automated inverted epifluorescent microscope
Tile Scan
Runs using Zen Blue
Objectives: 5x, 10x, 20x, 40x Dry, 63x Oil
B/W or color camera
Inverted epifluorescent microscope
No signup needed
Runs using Axiovision
B/W or Color Camera
Objectives: 2.5x, 4x, 10x, 20x, 40x Dry, 60x Oil
Photographs Provided by Steven R. McCaw, NIEHS Multimedia Servcies
Back
to Top
Last Reviewed: January 30, 2026