Frontiers | Real-Time Fast Scan Cyclic Voltammetry Detection and Quantification of Exogenously Administered Melatonin in Mice Brain
ORIGINAL RESEARCH article
Front. Bioeng. Biotechnol.
, 24 November 2020
Sec. Biomaterials
Volume 8 - 2020 |
Published in
Frontiers in Bioengineering and Biotechnology
Biomaterials
4.8
impact factor
8.8
citescore
Part of a Research Topic
Short-Term Versus Long-Term Challenges in Functional Biomaterials Interfacing Living Systems: Two Sides of the Coin
284k
views
17
articles
Edited by
Jian Yang
The Pennsylvania State University (PSU), United States
Reviewed by
Su-youne Chang
Mayo Clinic, United States
Xuemei Wang
Southeast University, China
Outline
Figures and Tables
FIGURE 1
View in article
FIGURE 2
View in article
FIGURE 3
View in article
FIGURE 4
View in article
FIGURE 5
View in article
TABLE 1
View in article
ORIGINAL RESEARCH article
Front. Bioeng. Biotechnol.
, 24 November 2020
Sec. Biomaterials
Volume 8 - 2020 |
Real-Time Fast Scan Cyclic Voltammetry Detection and Quantification of Exogenously Administered Melatonin in Mice Brain
Elisa Castagnola
Elaine M. Robbins
1,2
Kevin M. Woeppel
1,3
Moriah McGuier
Asiyeh Golabchi
1,3
I. Mitch Taylor
Adrian C. Michael
Xinyan Tracy Cui
1,3,5
1.
Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
2.
Department of Chemistry, University of Pittsburgh, Pittsburgh, PA, United States
3.
Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, United States
4.
Department of Chemistry, Saint Vincent College, Latrobe, PA, United States
5.
McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States
Article metrics
View details
Abstract
Melatonin (MT) has been recently considered an excellent candidate for the treatment of sleep disorders, neural injuries, and neurological diseases. To better investigate the actions of MT in various brain functions, real-time detection of MT concentrations in specific brain regions is much desired. Previously, we have demonstrated detection of exogenously administered MT in anesthetized mouse brain using square wave voltammetry (SWV). Here, for the first time, we show successful detection of exogenous MT in the brain using fast scan cyclic voltammetry (FSCV) on electrochemically pre-activated carbon fiber microelectrodes (CFEs).
In vitro
evaluation showed the highest sensitivity (28.1 nA/μM) and lowest detection limit (20.2 ± 4.8 nM) ever reported for MT detection at carbon surface. Additionally, an extensive CFE stability and fouling assessment demonstrated that a prolonged CFE pre-conditioning stabilizes the background,
in vitro
and
in vivo
, and provides consistent CFE sensitivity over time even in the presence of a high MT concentration. Finally, the stable
in vivo
background, with minimized CFE fouling, allows us to achieve a drift-free FSCV detection of exogenous administered MT in mouse brain over a period of 3 min, which is significantly longer than the duration limit (usually < 90 s) for traditional
in vivo
FSCV acquisition. The MT concentration and dynamics measured by FSCV are in good agreement with SWV, while microdialysis further validated the concentration range. These results demonstrated reliable MT detection using FSCV that has the potential to monitor MT in the brain over long periods of time.
Introduction
Melatonin (MT), the pineal gland’s major secretory product under dark conditions in all mammals, including humans (
Farías et al., 2012
), is well known for its role in circadian rhythms and modulation of the immune system (
Maestroni et al., 1986
Cagnacci et al., 1992
Szczepanik, 2007
Salehi et al., 2019
). MT is already recognized for the treatment of sleep disorder (
Jan et al., 1994
Buscemi et al., 2004
Xie et al., 2017
). Furthermore, MT is a multitasking molecule (
Reiter et al., 2010
) with anti-inflammatory, antioxidant (
Reiter et al., 2003
Hardeland, 2005
Reiter et al., 2016
), neuroprotective (
Túnez et al., 2004
Escribano et al., 2014
), anti-nociceptive (
Mukherjee et al., 2010
Wilhelmsen et al., 2011
), and anticonvulsant properties (
Fauteck et al., 1999
Banach et al., 2011
Aydin et al., 2015
). As an antioxidant, MT prevents neurotoxicity, oxidative stress, and neuroinflammation in experimental models of Parkinson’s (
Antolín et al., 2002
Mayo et al., 2005
) and Alzheimer’s disease (
Dragicevic et al., 2011
Rosales-Corral et al., 2012
Hossain et al., 2019
Luengo et al., 2019
). In addition, MT’s neuroprotective functions have shown therapeutic potentials for the treatment of amyotrophic lateral sclerosis (
Zhang et al., 2013
), Huntington’s disease (
Túnez et al., 2004
Escribano et al., 2014
), and cerebral ischemia (
Borlongan et al., 2000
Cuzzocrea et al., 2000
), while its anti-inflammatory and anti-nociceptive actions can alleviate chronic pain both in experimental (
Mukherjee et al., 2010
Wilhelmsen et al., 2011
) and clinical (
Korszun et al., 1999
Citera et al., 2000
) studies. Due to its lipophilic character, MT can easily cross the blood–brain barrier and enter both glia and neurons, making it an excellent therapeutic choice for central nervous system (CNS) disorders (
Miller et al., 2015
Golabchi et al., 2018
Salehi et al., 2019
). MT’s numerous physiological roles and potential therapeutic actions justify a strong need for real-time detection and monitoring of MT in the brain of laboratory animal models.
Previously, we have demonstrated detection of exogenously administered MT in anesthetized mouse brain using square wave voltammetry (SWV) (
Castagnola et al., 2020
). Fast scan cyclic voltammetry (FSCV) is an electroanalytical technique with higher temporal resolution (usually 100 ms) (
Robinson et al., 2003
Swamy and Venton, 2007
Wood and Hashemi, 2013
Oh et al., 2016
Ou et al., 2019
Puthongkham and Venton, 2020
) and, when used in combination with carbon fiber electrodes (CFEs), can achieve detection of sub-second fluctuations in neurotransmitter concentrations in real-time in the brain (
Keithley et al., 2011
Wood and Hashemi, 2013
Nguyen and Venton, 2014
Mark DeWaele et al., 2017
Castagnola et al., 2018
Puthongkham and Venton, 2020
). However, being primarily a background subtraction technique, FSCV measurements are limited to short time intervals (<90 s) due to the instability of the background currents, i.e., background drifting (
Oh et al., 2016
Oh et al., 2016
Mark DeWaele et al., 2017
Meunier et al., 2019
). This background drift can be attributed to a number of factors, comprising the changes occurring at the carbon surface itself—i.e., chemical reaction of electrode material, non-specific absorption of proteins, deposition of byproducts of electrochemical reactions (
Harreither et al., 2016
Hensley et al., 2018
Puthongkham and Venton, 2020
)—and changes in the surrounding chemical and biological neuro-environment—i.e., pH and local blood flow fluctuations (
Mark DeWaele et al., 2017
Roberts and Sombers, 2018
Meunier et al., 2019
). To predict the noise and extract the signal contribution from the drifting background, signal filtering (
Mark DeWaele et al., 2017
Puthongkham and Venton, 2020
), multivariate analyses (
Hermans et al., 2008
Meunier et al., 2019
), and waveform manipulations combined with mathematical techniques (
Oh et al., 2016
Meunier et al., 2019
) have been investigated, but they require training sets (
Johnson et al., 2016
Puthongkham and Venton, 2020
) and/or data preprocessing (
Puthongkham and Venton, 2020
). On the other hand, different electrochemical procedures have been shown to restore the sensitivity of the carbon surface and preserve their current stability and sensitivity both
in vitro
and
in vivo
Hafizi et al., 1990
Heien et al., 2003
Takmakov et al., 2010
), suggesting a potential alternative to stabilize the FSCV current background. Additionally, different FSCV waveforms (
Jackson et al., 1995
Ganesana et al., 2017
Hensley et al., 2018
Roberts and Sombers, 2018
) have been investigated for different analytes, to identify the best holding/switching potentials and scan rate combination that maximizes sensitivity while minimize fouling (
Heien et al., 2003
Cooper and Venton, 2009
Pyakurel et al., 2016
Cryan and Ross, 2019
Puthongkham and Venton, 2020
). Specifically for MT, Ross’ group (
Hensley et al., 2018
) has developed an optimized waveform that can minimize the electrode fouling due to MT oxidation byproduct deposition. Using this waveform, they demonstrated FSCV detection of MT in lymph node slices (
Hensley et al., 2018
).
To the best of our knowledge, real-time FSCV detection in the brain of living animals has not been previously reported. Here, we report a prolonged CFE electrochemical pre-conditioning protocol that stabilized the FSCV background for multiple minutes. Using the Ross’ waveform at pre-electrochemically conditioned CFEs, we successfully demonstrated a
drift-free
FSCV detection of exogenous MT
in vivo
for 3 min. To demonstrate and support the reliability of this FSCV approach, we (1) performed an extensive evaluation of CFE stability and fouling in the presence of 5 μM MT
in vitro
, (2) characterized
in vivo
FSCV signal baseline, and (3) evaluated the effects of biological tissue exposure on the impedance, capacitance, and sensitivity of the CFEs. Finally, we compared the
in vivo
MT concentrations measured by FSCV with those measured by SWV in our previous study (
Castagnola et al., 2020
) and used microdialysis from the tissue near the CFEs for further validation.
Materials and Methods
Microelectrode Fabrication
CFE Fabrication and Pre-conditioning
Carbon fiber electrodes were fabricated as previously described in
Taylor et al. (2012
2015)
, and
Castagnola et al. (2020)
. Briefly, borosilicate capillaries (0.4 mm ID, 0.6 mm OD; A-M systems Inc., Sequim, WA, United States), each containing a single carbon fiber (7 μm diameter, T650; Cytec Carbon Fibers LLC., Piedmont, SC, United States), were pulled to a fine tip using a vertical puller (Narishige, Los Angeles, CA, United States). The tip was sealed with epoxy (Spurr Epoxy; Polysciences Inc., Warrington, PA, United States) and the exposed fiber was cut 400 μm from the tip using a scalpel under an optical microscope (Szx12, Olympus). A mercury drop was injected into the barrel of the glass to create an electrical contact between the carbon fiber and a hookup wire (Nichrome; Goodfellow, Oakdale, PA, United States). CFEs were soaked in isopropyl alcohol (
Bath et al., 2000
) (Fisher Chemical, United States) for 20 min prior to use. The entire procedure that involved handling mercury was performed under a chemical fume hood, with the user wearing gloves, eye protection, a lab coat, and mask. After use, all electrodes and other mercury-contaminated materials were disposed of according to protocols required by Environmental Health and Safety of the University of Pittsburgh, in compliance with U.S. Department of Labor Occupational Safety and Health Administration compliance guideline 1910.120.
Carbon fiber electrode surfaces were preconditioned by applying the Ross’ FSCV waveform (0.2–1.3 V versus Ag/AgCl, 600 V/s) at 10 Hz overnight prior to the beginning of each experiment.
Microdialysis Probes and Procedures
Concentric style microdialysis probes were fabricated as previously described (
Nesbitt et al., 2015
Varner et al., 2016
Robbins et al., 2019
). Briefly, the probes were constructed in-house using hollow fiber membranes (18 kDa molecular weight cutoff, Spectra/Por RC, Spectrum, Rancho Dominguez, CA, United States) with a 280 μm OD, cut to a length of 1.5 mm. The inlet and outlet lines were made from fused silica capillary (75 μm ID, 150 μm OD, Polymicro Technologies, Phoenix, AZ, United States). Probes were perfused with artificial cerebrospinal fluid (aCSF; 142 mM NaCl, 1.2 mM CaCl
, 2.7 mM KCl, 1.0 mM MgCl
, 2.0 mM NaH
PO
, pH 7.4) at 2 μL/min using a gastight syringe (1000 Series Gastight Hamilton
TM
, Reno, NV, United States) driven by a syringe pump [Harvard Apparatus Model 11 (55-1199), Holliston, MA, United States] starting prior to insertion into the brain and their functionality was verified by placing the probe membrane into a beaker of 5 μM MT and detecting MT at the outlet. As aCSF does not have a carbonate buffer system, the pH was adjusted to pH 7.4, using NaOH and HCl (Sigma–Aldrich, MO, United States). Dialysate was analyzed for MT on a Shimadzu LCMS-2020 liquid chromatography mass spectrometer (LC-MS) using atmospheric pressure chemical ionization (APCI) by monitoring the [M + H]
peak at 233.1
m/z
. MT was separated using a gradient of 10–90% solvent A to solvent B over 10 min, where solvent A was acetonitrile with 0.1% formic acid, and solvent B was water with 0.1% formic acid. Data were analyzed using Shimadzu Lab Solution software and in MATLAB (Mathworks). Dialysate was diluted with ultrapure water (Nanopure, Barnstead, Dubuque, IA, United States) before analysis to protect the instrument from damage due to the high salt content of the sample.
In vitro
FSCV Calibration
Fast scan cyclic voltammetry was performed with an EI 400 potentiostat (Ensman Instruments; Bloomington, IN, United States) and the CV Tar Heels LabVIEW program (CV Tar Heels v4.3, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States). The headstage gain was set to 10
V/A. Data were analyzed using HDCV software (UNC Chapel Hill). The electrode was scanned using the Ross waveform, corresponding to a triangular waveform with a positive holding potential of 0.2 V, a 1.3 V switching potential, applied using a 600 V/s scan rate at 10 Hz (
Hensley et al., 2018
). MT was identified by inspection of the background-subtracted cyclic voltammograms. The MT oxidation peak occurred at 1.03 V (
Figures 1A,F
2B,D
4C
). Electrodes were calibrated using 0.1–5 μM MT concentrations dissolved in aCSF. The different concentrations were diluted starting from a freshly prepared 1 mM MT solutions. Calibration was performed in flow cell equipped with a pneumatically actuated injection valve with 500 μL sample loop (VICI AG International, Switzerland): flow through the system at 60 mL/h was driven with a syringe pump (
Taylor et al., 2017
).
FIGURE 1
FIGURE 2
Other analytes, such as DA and 5-HT that might interfere with MT detection, were tested using the same flow cell apparatus (
Supplementary Section 1
and
Supplementary Figures 1
for more consideration about possible neurotransmitter/MT metabolite interferences).
Electrochemical Characterization
Electrochemical impedance spectroscopy (EIS) measurements were used to investigate the electrode/solution interface prior to, during, and following implantation in the brain tissue, as previously described (
Taylor et al., 2019
Castagnola et al., 2020
). During the EIS measurements, a sine wave (10 mV RMS amplitude) was superimposed onto the open circuit potential while varying the frequency from 1 to 10
Hz. EIS was carried out using a potentiostat/galvanostat (Autolab, Metrohm, United States). The
in vitro
EIS was performed in aCSF in a three-electrode electrochemical cell set-up with a platinum counter electrode and an Ag/AgCl reference electrode.
In vivo
, a screw was used as counter electrode and the Ag/AgCl reference electrode was electrically connected via a salt bridge to the surface of the brain. Specifically, ca. 1 × 1 cm
square of Kimwipe (Kimtech
TM
Science Brand) was rolled and pulled through a pipet tip (volume 100–1250 μL, SureOne, Fisher Scientific, MA). The pipet tip was filled with aCSF and the reference electrode (CHI111P, CH Instruments Inc., TX) inserted into the pipet tip. The wet exposed part of the kimwipe is place in contact with the brain through a small pinhole craniotomy. Equivalent circuit modeling was performed using EIS Spectrum Analyzer 1.0. Model optimization was performed using a modified Levenburg–Marquardt algorithm with parametric weighting. A chi-square goodness of fit test was used to assess equivalent circuits describing the data. The variation of the FSCV current, defined here as the total current resulting from all faradaic and non-faradaic processes (i.e., background current) during the triangle voltage application, was recorded,
in vitro
and
in vivo
, using the EI 400 potentiostat and the CV Tar Heels LabVIEW program, and was evaluated by calculating (1) the charge storage capacity (CSC, mC/cm
) as
in an entire CV cycle and (2) the capacitance (C,nF) as
In vivo
Procedures
All procedures involving animals were approved by the Institutional Animal Care and Use Committee of the University of Pittsburgh. CFEs were acutely implanted in the visual cortex of male mice (C57BL/6J, 8–12 weeks, 22–35 g; Jackson Laboratory, Bar Harbor, ME, United States): this strain was selected for their low endogenous MT levels (
Roseboom et al., 1998
). Anesthesia was induced with 1.5–2% isoflurane mixed with oxygen flow at 1 L/min and maintained with 1.25–1.5%. Body temperature was maintained at 37°C with a thermostatic heating pad (Harvard Apparatus, Holliston, MA, United States) and eye lubrication was maintained with lacrigel (Dechra Puralube Vet Ointment). The implantation procedures have been performed as previously reported (
Castagnola et al., 2020
). Briefly, the animal’s head was fixed in a stereotaxic frame (Narishige International USA, Inc.). In
= 12 mice, a pinhole craniotomy was made over the visual cortex (1.0 mm anterior to lambda and 1.5 mm lateral from midline) with a high-speed drill (0.007 drill bit, Fine Science Tools, Inc., Foster City, CA, United States). An additional pinhole craniotomy was made to establish the connection to the reference electrode via a salt bridge. CFEs were lowered 0.8 mm below the brain surface.
Following insertion into the tissue, the CFE was subjected to the Ross FSCV waveform applied at 10 Hz for at least 30 min for stabilization. After the stabilization period, the animal received an intraperitoneal (i.p.) injection of 180 mg/kg MT (
= 5) (99 + % Alfa Aesar, Haverhill, MA, United States) or a volume-matched injection of saline (
= 2), followed by 3 min of FSCV recording. Similarly to our previous studies (
Golabchi et al., 2018
Castagnola et al., 2020
), 10 μL dimethylsulfoxide (DMSO, 99% Alfa Aesar, Haverhill, MA, United States) was added in order to improve the solubility of the MT in 100 μL saline vehicle. 10 μL of DMSO was also added to the saline vehicle for the control group, in order to exclude the DMSO effect on the background stability.
In another
= 5 mice, FSCV and microdialysis were performed simultaneously. In this case, the borosilicate glass tube of a CFE was glued to the stainless-steel housing of microdialysis probe. A larger craniotomy was performed to permit insertion of the devices. Then the microdialysis probes were perfused with aCSF at 2 μL/min using a gastight syringe driven by a syringe pump (Harvard Apparatus, Holliston, MA, United States) for 1 h, while electrochemical stabilization of the CFE surface was performed. Immediately after, mice received a single 180 mg/kg, i.p. injection of MT, and FSCV measurements were performed and dialysate collected.
At the end of the
in vivo
measurement, the CFEs were removed from the brain with the help of the micromanipulator, washed with abundant DI water followed by post calibration. Then, the Ross’ waveform was applied to the CFEs overnight (≥12 h) at 600 V/s or, a more aggressive FSCV waveform (−0.5 to 1.9 V versus Ag/AgCl and back at 400 V/s) was applied for 2 min, to remove the biological encapsulation and restore the CFE surface (see
Supplementary Section 3
and
Supplementary Figures 4
, 10). In our previous study, we have demonstrated that this aggressive FSCV waveform (−0.5 to 1.9 V versus Ag/AgCl and back at 400 V/s) was able to clean the CFEs from biological matter encapsulation after the extraction from the brain, preserving the CFE integrity (
Castagnola et al., 2020
). The post-calibration was repeated ≥ 4 h after the electrochemical cleaning procedure.
Statistical Analyses
Statistical analyses were conducted using IBM SPSS software (v22, IBM Corp., Armonk, NY, United States) and Origin Pro 8.1 (OriginLab Corp., Northampton, MA, United States). One-way ANOVA with Bonferroni post-tests was used to compare changes in the sensitivity of CFEs to MT in presence of MT (continuous FSCV scanning)
in vitro
. One-way repeated measures ANOVA with Bonferroni post-tests was used to calculate the variations in MT sensitivity over time during consecutive MT injections
in vitro
, and the changes in CSC (mC/cm
) and capacitance (C,nF), as defined in Section “Electrochemical Characterization,” over time
in vivo.
Two-way repeated measures ANOVA with Bonferroni post-tests was used to compare the EIS changes before, during, and following brain implant. Significance was determined at
< 0.05.
Results and Discussion
In vitro
FSCV Sensitivity and Selectivity
Melatonin oxidizes at carbon-based electrodes following a three-step reaction (
Xiao-Ping et al., 2002
Vasantha and Chen, 2005
Hensley et al., 2018
) involving the formation of a quinoneimine, which is both highly reactive and susceptible to electropolymerization, causing undesirable adsorption products to foul the electrode surface (
Xiao-Ping et al., 2002
Vasantha and Chen, 2005
Hensley et al., 2018
). To minimize the extent of MT fouling, the Ross’ group optimized a FSCV waveform that combines a positive holding potential (0.2 V) and a faster scan rate (600 V/s) (
Hensley et al., 2018
). Furthermore, the use of a 1.3 V switching potential has shown to maximize the sensitivity of the primary oxidation peak (
Hensley et al., 2018
).
Using this waveform, we evaluated the sensitivity of our CFE in detecting MT
in vitro
with a range of MT concentration of 0.1–5 μM in aCSF. The background subtracted CVs corresponding to this range of concentrations demonstrate clear oxidation peaks at 1.03 V, as reported in
Figure 1A
. The sensitivity is determined to be 28.1 nA/μM, based on the linear regression slope of the maximum faradaic current versus MT concentration plot. The average calibration plot (±SEM,
= 6) follows a linear trend (
Figure 1B
), including linear regression fit (
> 0.990). Our sensitivity (28.1 nA/μM) is four times higher than what was reported in
Hensley et al. (2018)
, which is likely due to the four times larger surface area of our CFEs. The lower detection limit (LOD), defined as three times the standard deviation of the noise, was estimated to be 20.2 ± 4.8 nM (
= 7), which is the lowest LOD value reported in literature using carbon-based materials and electrochemical detection methods for MT detection (
Levent, 2012
Gomez et al., 2015
Apetrei and Apetrei, 2016
Neeraj Kumar, 2017
). The selectivity of MT detection at CFEs using this FSCV waveform over other electroactive species, including ascorbic acid (AA), dopamine (DA), serotonin (5-HT) and their mixtures, and H
has been evaluated. The results have shown that MT can be distinguished among the most common electroactive neurotransmitters in the brain (data reported in
Supplementary Figures 1
and
Supplementary Section 1
).
In vitro
FSCV Stability and Electrode Fouling
The stability of CFEs is important for monitoring MT variations over an extended duration of time in vivo (
Mark DeWaele et al., 2017
Roberts and Sombers, 2018
). As previously mentioned, one major limitation of traditional FSCV measurements is related to the instability of the background currents, i.e., background drift, that limits the FSCV data analysis to short time intervals (<90 s) (
Mark DeWaele et al., 2017
Meunier et al., 2019
).
Here, to evaluate the effect of a prolonged CFE pre-conditioning on the background stability and MT sensitivity over time, we applied the Ross’ FSCV waveform (0.2–1.3 V versus Ag/AgCl, 600 V/s) at 10 Hz to CFE electrodes in aCSF overnight prior to the beginning of each experiment. This corresponds to cycling the CFEs for about 2 h at 60 Hz using the same waveform, longer than what previously reported (15 min at 60 Hz) (
Takmakov et al., 2010
Meunier et al., 2020
). This pre-conditioning procedure stabilized the current background
in vitro
, as can be observed in the representative color plots for nine repetitions of 1 μM MT bolus injections during a 3-min collection in aCSF (
Figures 1C,D
). Using a 15 min conditioned CFE, the electrochemical drift started after 30 s, increased with time and, after about 2 min, the MT oxidation peak was no longer detectable because of the background instability (
Figure 1C
). In contrast, after the overnight pre-conditioning of the same CFE, we did not observe any background drift along the 3-min recording window (
Figure 1D
). The current amplitudes (average and SEM,
= 5 CFEs) of the oxidation peak at 1.03 V collected for the 30 repetitions along 10 min are reported in the bar plot in
Figure 1E
. The averaged current peak amplitudes (first: 42.7 ± 8.6 nA, last 41.3 ± 5.5 nA,
= 5) are not significantly affected by time during nine consecutive injections [repeated measures ANOVA,
(7,42) = 0.235,
> 0.05].
Electrochemical procedures have been used before sensing to pretreat carbon surface and activate the surface with functional groups that may improve detection (
Engstrom and Strasser, 1984
Bowling et al., 1989
Cao et al., 2019
), or during sensing to regenerate electrochemically active surfaces and restore the sensitivity of carbon microelectrodes affected by irreversible non-specific adsorption of biomolecules (
Takmakov et al., 2010
). In particular, oxidation of carbon surfaces using triangular waveforms with a switching potential higher than 1 V (i.e., 1.3 and 1.4 V versus Ag/AgCl) has been shown to preserve the current stability for DA detection both
in vitro
and
in vivo
Hafizi et al., 1990
Heien et al., 2003
Takmakov et al., 2010
) as a result of continuous carbon surface renewal (
Takmakov et al., 2010
). To our knowledge, the effect of a prolonged electrochemical preconditioning, in conjunction with continuous regeneration of the CFE surface, on FSCV background stability has not been reported.
The electrochemical pretreatments can have multiple effects on the electrode surface, and can (1) affect the concentration of physisorbed impurities on the carbon surface, i.e., electrode cleanliness (
Bowling et al., 1989
), (2) create surface oxygen-functional groups (
Engstrom and Strasser, 1984
Bowling et al., 1989
Cao et al., 2019
), (3) alter the carbon substrate structure due to the formation or removal of defects, in particular affecting the graphitic edge plane density (
Poon et al., 1988
Bowling et al., 1989
), and (4) modify the microscopic surface area (
Poon et al., 1988
Bowling et al., 1989
). The extent of these effects is likely to be dependent upon the number of electrochemical cycles or duration of the treatment. Here, we monitored the impedance and the FSCV current, i.e., background current during the triangle voltage application, during the electrochemical pre-conditioning. The impedance spectra and FSCV plots at different time points are reported in
Supplementary Figure 3
. We observed a fast decrease in impedance and corresponding increase in FSCV current during the first 45 min. After that, these trends slowed down over time, and after 8 h of FSCV cycling at 10 Hz, both impedance and FSCV current maintained the stability for the following 16 h (under continuous cycling). The starting 45-min fast trend in impedance reduction and current increase is likely due to the separation of graphite planes (
Maeda et al., 1985
Bowling et al., 1989
), known to be the first step of the electrochemical activation (
Bowling et al., 1989
), with consequent fracturing of the graphite lattice and formation of edge plane defects. The formation of functional groups during the electrochemical conditioning has shown to further facilitate this phenomenon by creating strains in the lattice which causes edge planes to form and planes to delaminate (
Bowling et al., 1989
). The continuous FSCV cycling at 10 Hz with the 1.3 V switching potential likely increases the amount of oxygen groups at the surface and continues to favor this “activation process” until the maximum amount of defects is formed, at which point the carbon electrode surface reaches a stable state and we no longer observe impedance or FSCV current change upon cycling. SEM images of a pristine CFE, a CFE at which the Ross’ waveform was applied overnight (≥12 h) at 600 V/s and a CFE at which a more aggressive FSCV waveform (−0.5 to 1.9 V versus Ag/AgCl and back at 400 V/s) was applied for 2 min are reported in
Supplementary Figure 4
. The integrity of the CFE seems to be preserved after the electrochemical pretreatments.
To test the
in vitro
CFE stability to MT detection over time, we monitored the response of 1 μM bolus injections of MT every 3 min for more than 8 h. The background subtracted CV plots at different time points (from Repetition 1, corresponding to time zero, to Repetition 150, corresponding to 8 h of FSCV scanning) are reported in
Figure 1F
. Despite variations in the current baseline, the MT oxidation peak was not affected over time, presenting a minimal 0.74% variation in current amplitude.
These results indicated the effectiveness of the prolonged CFE pre-conditioning on the background stabilization and the stability of the FSCV MT sensitivity over time. However, because the CFE
were exposed to MT only during the bolus MT injection (approximately 5 s), these experiments only partially represent the
in vivo
MT fouling situation. Thus, to estimate the CFE fouling in the presence of MT, CFEs were cycled using the Ross waveform for 1 h in aCSF containing a 5 μM MT concentration. The results are reported in
Figure 2
. The CFE sensitivity to a bolus injection of 1 μM MT and 5 μM MT was tested before and after the FSCV cycling in MT and the peak amplitudes of MT oxidation were not significantly changed, both for the detection of 1 μM MT (one-way ANOVA,
= 0.14; Bonferroni post-tests n.s.) (
Figures 2A,B
) and 5 μM MT (one-way ANOVA,
= 0.31; Bonferroni post-tests n.s.) (
Figures 2C,D
). This result suggests that the optimized waveform is effective in preserving the electrode from fouling even in the presence of a high MT concentration. Additionally, the use of a 1.3 V switching potential, regenerating a fresh CFE surface by continuous etching of the carbon electrode (
Takmakov et al., 2010
Keithley et al., 2011
), may helped to mitigate the fouling.
We should note that we purposefully designed a highly aggressive
in vitro
fouling resistance test by challenging the CFE with high concentrations of MT. In our previous study, 5.5 μM of MT corresponded to the peak concentration detected in the mouse brain after administration of high MT dose (180 mg/kg), which only lasted for a few minutes before MT being metabolized (
Castagnola et al., 2020
).
Evaluation of CFE Fouling
in vivo
and Effect of Tissue Exposure on CFE Sensitivity
Recent works from the Sombers’ group have suggested that the FSCV current can be used as a predictor of electrode fouling and sensitivity to multiple analytes
in situ
Roberts et al., 2013
Meunier et al., 2017
). Furthermore, EIS has been considered a valuable technique to probe electrode conditions and biofouling (
Wilks et al., 2012
Alba et al., 2015
), as well as predict electrochemical FSCV performance, using equivalent circuit models of the electrode/solution interface (
Roberts et al., 2013
Meunier et al., 2020
). Thus, to gain further insight about the extent of fouling
in vivo
and changes of electrode/tissue interface, we monitored (1) the EIS of the CFEs
in vivo
, upon probe implantation and after the experimental sessions (composed of a 30–40 min of pre-conditioning with FSCV, MT injection and a 40 min post-injection FSCV, total of ∼80 min) and (2) the variation of the FSCV current
in vivo
before, during and after the MT injection (
Figure 3
). Additionally, to estimate the effects of tissue exposure on impedance, capacitance, and sensitivity of the CFEs, (1) EIS and FSCV current were measured before implantation and after explantation in aCSF and (2) the sensitivity of CFEs before and after tissue exposure
in vitro
. All EIS data were fitted to an equivalent circuit model (
Supplementary Section 2
and
Supplementary Figure 5
) in order to better investigate the nature of impedance changes.
FIGURE 3
FIGURE 4
In vivo
, little change in FSCV current, during and after the MT injection was observed (
Figure 3A
). The CSC (mC/cm
) (
Figure 3B
) and the capacitance (C,nF) (
Figure 3C
), calculated from the FSCV current, did not significantly change at different time points before and after the MT injection [repeated measures ANOVA,
(5,25) = 0.172,
> 0.05 for CSC;
(8,32) = 0.445,
> 0.05, multiple comparisons Bonferroni post-tests n.s.]. Similarly, the impedance spectra (
Figures 3D–F
) did not significantly change during the experimental session of ≥ 80 min [two-way ANOVA with repeated measures:
(1,312) = 1.287,
= 0.2576 > 0.05].
Average Nyquist plots (
= 6) of the experimental data and the corresponding curve-fitting of the most appropriate equivalent circuit model, i.e., a non-ideal Randles, are reported in
Figures 3D–F
and
Supplementary Figure 6
. More details about the model and the effect of tissue exposure are provided in
Supplementary Section 2
. Briefly, the non-ideal Randles equivalent circuit (
Figure 3D
inset) consists of a solution resistance (R
sol+carbon
) in series with a constant phase element (Z
CPE
). This is consistent with results reported in the literature for CFEs glue-sealed at the tip (
Meunier et al., 2020
). The constant phase element (Z
CPE
) is define as: Z
CPE
= 1/(jω)
, where Y
represents the double-layer capacitance and
is a constant related to the angle of rotation in the complex plane compared to the purely capacitive behavior (
= 1 for a pure capacitor) (
MacDonald, 1987
Nimbalkar et al., 2018
Meunier et al., 2020
). The parameters obtained by fitting the experimental data to the model are reported in
Table 1
TABLE 1
sol+carbon
(kΩ)
(nS s
In vitro
in aCSF, pre implant
5.3
3.4
0.853
In vivo
time 0 (immediately after insertion in the brain)
9.2
3.7
0.829
In vivo
time ∼80 min (after conditioning and measurements)
9.0
3.8
0.815
In vitro
in aCSF, post implant
6.9
3.6
0.833
Equivalent circuit model fit parameters.
Immediately after CFEs were inserted in the brain, we observed (1) an increase in the real impedance, with a deviation from the ideal capacitor (
Supplementary Figure 6
), confirmed by the decrease of
values obtained from the fitting (
Table 1
) and (2) an increase of the solution/CFE interface resistance R
sol+carbon
Table 1
and
Supplementary Figure 7
), most likely due to the more complex and resistive nature of the brain tissue compared to the aCSF, and may also be affected by the use of a different three-electrochemical system
in vivo
Williams et al., 2007
Mercanzini et al., 2009
Meunier et al., 2020
). It is important to note that the
values we measured from the
in vitro
EIS of CFEs are lower than what was reported in literature for similar CFEs (ca. 0.9) (
Meunier et al., 2020
). This is due to the effect of the overnight pre-conditioning, as the starting
value before pre-conditioning was 0.891. The higher Y
in vivo
is likely due to the higher ionic strength of the tissue in comparison with aCSF, which decreases the diffuse layer thickness and increases double-layer capacitance (
Bard et al., 1980
Meunier et al., 2020
). During the
in vivo
measurements, all circuit parameters remain relatively steady. These results showed no significant evidence of CFE fouling during the duration of the
in vivo
experiments, consistent with the
in vitro
finding.
In vivo
MT Detection Using FSCV
Finally, we used FSCV to detect MT in the visual cortex of mouse brains in response to an i.p. injection of 180 mg/kg MT (
Albertson et al., 1981
Sugden, 1983
). In our recent SWV study, we demonstrated that the i.p. administration of this dosage creates fast changes in the MT concentration in the mouse brain (
Castagnola et al., 2020
). Similar MT dosages have shown to possess anticonvulsant effects and to reduce the seizure rank score in rat models of epilepsy (
Albertson et al., 1981
Aydin et al., 2015
). MT supplements in similar concentrations have also shown to ameliorate sleep deprivation-aggravated pain behavior and neuropathic pain in rats with chronic constriction nerve injury (
Huang et al., 2014
). MT administered intraperitoneally has specifically demonstrated to possess a strong antinociceptive and analgesic effect (
Sugden, 1983
Yu et al., 2000
) and to potentiate sleep in mice and rats (
Sugden, 1983
Wang et al., 2002
).
Prior to the beginning of each
in vivo
experiment, CFEs were electrochemically pre-conditioned overnight in aCSF
in vitro
, as described in the previous section. After the implantation of CFEs in the visual cortex, the microelectrode surfaces were further stabilized by applying the same FSCV waveform at 10 Hz. Stable current backgrounds were observed after about 30–40 min of FSCV scanning.
The representative color plot for a 3-min FSCV background-subtracted current collection
in vivo
Supplementary Figure 11a
) and the average FSCV background (
= 10, black,
Supplementary Figure 11b
), collected before each MT recording session, show a stable background without observable current drift. Additionally, no changes were observed in the background subtracted CV after the injection of saline vehicle (
Figure 4A
). MT was administered i.p. at 180 mg/kg MT 10 s after the beginning of the FSCV acquisition. CFEs started to detect MT in the brain about 50 s following the i.p. injection (
Figure 4B
). The detection of MT using FSCV is clearly confirmed by the color plot current changes (
Figure 4B
) and by the background subtracted CVs, showing an increase of the current amplitude of the characteristic MT peak at 1.03 V over time, as seen in
Figure 4C
Our previous SWV studies (
Taylor et al., 2019
Castagnola et al., 2020
) have concluded that there is a drastic decrease in CFE sensitivity after it is explanted from the brain tissue and this is mainly attributed to the encapsulation of the CFE by biological matter pulled out during the explantation process itself. For this reason, we used the pre-calibration curve of electrode sensitivity to determine the
in vivo
MT concentrations. Measured MT concentration (±SEM) was plotted over time before and after the MT injection (
= 10, red,
Figure 4D
) and showed a linear increase after 50 s and reached 0.51 μM (0.40 μM min, 0.62 μM max) after 170 s. In comparison, the average baseline (background-subtracted FSCV) after injection of saline vehicle (
= 2, black,
Figure 4D
) remained flat.
In summary, the CFE electrochemical pre-conditioning enabled a stable FSCV background over a recording session of 3 min, more than twice the duration limit (usually < 90 s) reported in literature for FSCV measurements before the background drifting occurs, which has prevented accurate analysis of chemical fluctuations in the brain (
Mark DeWaele et al., 2017
Meunier et al., 2019
). This allowed us to obtain stable FSCV detection of MT
in vivo
for 3 min.
Comparison With SWV and Microdialysis
Remarkably, when comparing the
in vivo
MT concentrations detected using FSCV to those obtained in our previous SWV study (
Castagnola et al., 2020
), during the 170 s post i.p. injection of 180 mg/kg MT, we observed a very similar trend (
Figure 5
). The averaged detected concentrations at 170 s after MT administration were 0.55 μM (0.40 μM min, 0.64 μM max) for FSCV and 0.53 μM (0.32 μM min, 0.82 μM max) for SWV. It is worth noting that FSCV provides 240 times greater temporal resolution (0.1 versus 24 s) and 200 times higher sensitivity (28.1 versus 0.14 nA/μM) than SWV.
FIGURE 5
To provide a further validation of our electrochemical MT quantification, we compared the electrochemical results with microdialysis, by simultaneously performing microdialysis and FSCV experiments in the same location of same mice (
= 5). The dialysate, collected for 40 min before and after i.p. injection, was analyzed using LC-MS, i.e., injected onto an LC-MS and compared to a calibration curve. First of all, no MT peak was observed in baseline dialysate collected before the MT administration (
Supplementary Figure 12
). This is in agreement with the known low endogenous MT background in C57BL.6J mice (
Roseboom et al., 1998
). After MT injection, we obtained an average concentration of 4.3 μM (
= 5, 3.34 min and 6.69 max) from the dialysate collected for 40 min, which is on the same order of magnitude of the MT concentration detected with the SWV measurement [maximum detected concentration was 5.5 μM (4.4 μM min, 6.5 μM max) after 17.9 minutes following the MT administration] (
Castagnola et al., 2020
). It is worth pointing out that one cannot expect a perfect match between microdialysis and electrochemical results. Our electrochemical detections use pre-calibration, which may provide an underestimation of the MT
in vivo
concentration. On the other hand, the microdialysis result is an underestimation due to the impact of the microdialysis probes on the brain tissues and the corresponding recovery factor (
Yang et al., 2000
Watson et al., 2006
Jaquins-Gerstl and Michael, 2015
). Furthermore, there are clear differences in temporal resolution between the microdialysis (averaged over 40 min) and electrochemical methods (measured at subseconds for FSCV and seconds for SWV) (
Watson et al., 2006
Jaquins-Gerstl and Michael, 2015
Puthongkham and Venton, 2020
). Nevertheless, having the estimated MT concentrations in the same range supports the reliability of FSCV and SWV to measure MT in real time in mouse brain.
Conclusion
In this study, we established a prolonged CFE electrochemical pre-conditioning protocol to enable stable FSCV background and demonstrated that pre-conditioning CFE with the Ross’s FSCV waveform overnight resulted in a stable sensitivity in response to 1 μM bolus injections of MT over a period of 8 h, or in the prolonged presence of a high MT concentration of 5 μM. Using the FSCV current and EIS as a predictor of the electrode/solution interface variations, we estimated the extent of fouling
in vivo
, and the effects of the tissue exposure on the impedance, capacitance, and sensitivity of the CFEs. We found no significant evidence of CFE fouling during the duration of the
in vivo
experiments, confirming the result obtained
in vitro
. Remarkably,
in vivo
measurements demonstrated a
drift-free
FSCV detection of exogenous MT in mouse brain for 3 min,004 more than twice the duration limit (usually < 90 s) reported in literature before FSCV background drifting occurs (
Mark DeWaele et al., 2017
Meunier et al., 2019
). The
in vivo
MT concentrations measured by FSCV are consistent with those measured by SWV upon the same MT injection regime (
Castagnola et al., 2020
), which is also supported by microdialysis. These results support the ability and reliability of FSCV to measure exogenously delivered MT
in real time
over several minutes
in vivo
Statements
Data availability statement
The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.
Ethics statement
All procedures involving animals were approved by the Institutional Animal Care and Use Committee of the University of Pittsburgh.
Author contributions
EC led
in vitro
and
in vivo
experiments, performed
in vitro
and
in vivo
fouling experiments and data analysis, and wrote the manuscript. ER fabricated microdialysis probes and led microdialysis experiments and analysis. KW performed parts of the surgeries and SEM imaging. AG performed parts of the surgeries. MM performed impedance measurements and
in vitro
calibrations and helped with CFEs fabrication. IT fabricated the CFEs, supervised the
in vitro
and fouling experiments, and edited the manuscript. AM supervised the microdialysis experiments and edited the manuscript. XTC supervised the project, guided the data analysis, and edited the manuscript. All authors contributed to the article and approved the submitted version.
Funding
This work was supported by NIH (Grants R01NS062019, R01NS089688, R21DA043817, and R21 DA049592).
Acknowledgments
We thank Neha Chodapaneedi and Julian Metro for helping with CFE fabrication and characterization.
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Supplementary material
The Supplementary Material for this article can be found online at:
References
Alba
N. A.
Du
Z. J.
Catt
K. A.
Kozai
T. D.
Cui
X. T.
2015
).
In vivo electrochemical analysis of a PEDOT/MWCNT neural electrode coating.
Biosensors
618
646
10.3390/bios5040618
Pubmed Abstract
CrossRef
Google Scholar
Albertson
T. E.
Peterson
S.
Stark
L.
Lakin
M.
Winters
W.
1981
).
The anticonvulsant properties of melatonin on kindled seizures in rats.
Neuropharmacology
20
61
66
10.1016/0028-3908(81)90043-5
CrossRef
Google Scholar
Antolín
I.
Mayo
J. C.
Sainz
R. M.
del Brío
Mde L.
Herrera
F.
Martín
V.
et al
2002
).
Protective effect of melatonin in a chronic experimental model of Parkinson’s disease.
Brain Res.
943
163
173
10.1016/s0006-8993(02)02551-9
CrossRef
Google Scholar
Apetrei
I. M.
Apetrei
C.
2016
).
Voltammetric determination of melatonin using a graphene-based sensor in pharmaceutical products.
Int. J. Nanomed.
11
1859
1866
10.2147/ijn.s104941
Pubmed Abstract
CrossRef
Google Scholar
Aydin
L.
Gundogan
N. U.
Yazici
C.
2015
).
Anticonvulsant efficacy of melatonin in an experimental model of hyperthermic febrile seizures.
Epilepsy Res.
118
49
54
10.1016/j.eplepsyres.2015.11.004
Pubmed Abstract
CrossRef
Google Scholar
Banach
M.
Gurdziel
E.
Jędrych
M.
Borowicz
K. K.
2011
).
Melatonin in experimental seizures and epilepsy.
Pharmacol. Rep.
63
11
10.1016/s1734-1140(11)70393-0
CrossRef
Google Scholar
Bard
A.
Faulkner
L.
Leddy
J.
Zoski
C.
1980
).
Electrochemical Methods: Fundamentals and Applications.
New York, NY
Wiley
Google Scholar
Bath
B. D.
Michael
D. J.
Joseph
J. D.
Runnels
P. L.
Wightman
R. M.
2000
).
Subsecond Adsorption and Desorption of Dopamine at Carbon-Fiber Microelectrodes.
Anal. Chem.
72
5994
6002
10.1021/ac000849y
Pubmed Abstract
CrossRef
Google Scholar
Borlongan
C. V.
Yamamoto
M.
Takei
N.
Kumazaki
M.
Ungsuparkorn
C.
Hida
H.
et al
2000
).
Glial cell survival is enhanced during melatonin-induced neuroprotection against cerebral ischemia.
FASEB J.
14
1307
1317
10.1096/fj.14.10.1307
Pubmed Abstract
CrossRef
Google Scholar
10
Bowling
R.
Packard
R. T.
McCreery
R. L.
1989
).
Mechanism of electrochemical activation of carbon electrodes: role of graphite lattice defects.
Langmuir
683
688
10.1021/la00087a022
CrossRef
Google Scholar
11
Buscemi
N.
Vandermeer
B.
Pandya
R.
Hooton
N.
Tjosvold
L.
Hartling
L.
et al
2004
).
Melatonin for treatment of sleep disorders.
Evid. Rep. Technol. Assess.
108
Google Scholar
12
Cagnacci
A.
Elliott
J.
Yen
S.
1992
).
Melatonin: a major regulator of the circadian rhythm of core temperature in humans.
J. Clinic. Endocrinol. Metab.
75
447
452
10.1210/jc.75.2.447
CrossRef
Google Scholar
13
Cao
Q.
Puthongkham
P.
Venton
B. J.
2019
).
new insights into optimizing chemical and 3D surface structures of carbon electrodes for neurotransmitter detection.
Analytic. Methods
11
247
261
10.1039/c8ay02472c
Pubmed Abstract
CrossRef
Google Scholar
14
Castagnola
E.
Vahidi
N. W.
Nimbalkar
S.
Rudraraju
S.
Thielk
M.
Zucchini
E.
et al
2018
).
In vivo dopamine detection and single unit recordings using intracortical glassy carbon microelectrode arrays.
MRS Advances
1629
10.1557/adv.2018.98
Pubmed Abstract
CrossRef
Google Scholar
15
Castagnola
E.
Woeppel
K.
Golabchi
A.
McGuier
M.
Chodapaneedi
N.
Metro
J.
et al
2020
).
Electrochemical detection of exogenously administered melatonin in the brain.
Analyst
145
2612
2620
10.1039/d0an00051e
CrossRef
Google Scholar
16
Citera
G.
Arias
M.
Maldonado-Cocco
J.
La
M.
Rosemffet
M.
Brusco
L.
et al
2000
).
The effect of melatonin in patients with fibromyalgia: a pilot study.
Clinic. Rheumatol.
19
13
10.1007/s100670050003
Pubmed Abstract
CrossRef
Google Scholar
17
Cooper
S. E.
Venton
B. J.
2009
).
Fast-scan cyclic voltammetry for the detection of tyramine and octopamine.
Analytic. Bioanalytic. Chem.
394
329
336
10.1007/s00216-009-2616-0
Pubmed Abstract
CrossRef
Google Scholar
18
Cryan
M. T.
Ross
A. E.
2019
).
Scalene Waveform for Codetection of Guanosine and Adenosine Using Fast-Scan Cyclic Voltammetry.
Analytic. Chem.
91
5987
5993
10.1021/acs.analchem.9b00450
Pubmed Abstract
CrossRef
Google Scholar
19
Cuzzocrea
S.
Costantino
G.
Gitto
E.
Mazzon
E.
Fulia
F.
Serraino
I.
et al
2000
).
Protective effects of melatonin in ischemic brain injury.
J. Pineal Res.
29
217
227
Google Scholar
20
Dragicevic
N.
Copes
N.
O’Neal-Moffitt
G.
Jin
J.
Buzzeo
R.
Mamcarz
M.
et al
2011
).
Melatonin treatment restores mitochondrial function in Alzheimer’s mice: a mitochondrial protective role of melatonin membrane receptor signaling.
J Pineal Res.
51
75
86
10.1111/j.1600-079x.2011.00864.x
Pubmed Abstract
CrossRef
Google Scholar
21
Engstrom
R. C.
Strasser
V. A.
1984
).
Characterization of electrochemically pretreated glassy carbon electrodes.
Analytic. Chem.
56
136
141
10.1021/ac00266a005
CrossRef
Google Scholar
22
Escribano
B. M.
Colin-Gonzalez
A. L.
Santamaría
A.
Túnez
I.
2014
).
The role of melatonin in multiple sclerosis, Huntington’s disease and cerebral ischemia.
CNS Neurol. Disord. Drug Targets
13
1096
1119
10.2174/1871527313666140806160400
Pubmed Abstract
CrossRef
Google Scholar
23
Farías
J. G.
Zepeda
A. B.
Calaf
G. M.
2012
).
Melatonin protects the heart, lungs and kidneys from oxidative stress under intermittent hypobaric hypoxia in rats.
Biol. Res.
45
81
85
10.4067/s0716-97602012000100011
Pubmed Abstract
CrossRef
Google Scholar
24
Fauteck
J.-D.
Schmidt
H.
Lerchl
A.
Kurlemann
G.
Wittkowski
W.
1999
).
Melatonin in epilepsy: first results of replacement therapy and first clinical results.
Neurosignals
105
110
10.1159/000014577
Pubmed Abstract
CrossRef
Google Scholar
25
Ganesana
M.
Lee
S. T.
Wang
Y.
Venton
B. J.
2017
).
Analytical techniques in neuroscience: recent advances in imaging, separation, and electrochemical methods.
Analytic. Chem.
89
314
341
10.1021/acs.analchem.6b04278
Pubmed Abstract
CrossRef
Google Scholar
26
Golabchi
A.
Wu
B.
Li
X.
Carlisle
D. L.
Kozai
T. D.
Friedlander
R. M.
et al
2018
).
Melatonin improves quality and longevity of chronic neural recording.
Biomaterials
180
225
239
10.1016/j.biomaterials.2018.07.026
Pubmed Abstract
CrossRef
Google Scholar
27
Gomez
F. J. V.
Martín
A.
Silva
M. F.
Escarpa
A.
2015
).
Screen-printed electrodes modified with carbon nanotubes or graphene for simultaneous determination of melatonin and serotonin.
Microchim. Acta
182
1925
1931
10.1007/s00604-015-1520-x
CrossRef
Google Scholar
28
Hafizi
S.
Kruk
Z. L.
Stamford
J. A.
1990
).
Fast cyclic voltammetry: improved sensitivity to dopamine with extended oxidation scan limits.
J. Neurosci. Methods
33
41
49
10.1016/0165-0270(90)90080-y
CrossRef
Google Scholar
29
Hardeland
R.
2005
).
Atioxidative protection by melatonin.
Endocrine
27
119
130
Google Scholar
30
Harreither
W.
Trouillon
R.
Poulin
P.
Neri
W.
Ewing
A. G.
Safina
G.
2016
).
Cysteine residues reduce the severity of dopamine electrochemical fouling.
Electrochim. Acta
210
622
629
10.1016/j.electacta.2016.05.124
CrossRef
Google Scholar
31
Heien
M. L.
Phillips
P. E.
Stuber
G. D.
Seipel
A. T.
Wightman
R. M.
2003
).
Overoxidation of carbon-fiber microelectrodes enhances dopamine adsorption and increases sensitivity.
Analyst
128
1413
1419
10.1039/b307024g
Pubmed Abstract
CrossRef
Google Scholar
32
Hensley
A. L.
Colley
A. R.
Ross
A. E.
2018
).
Real-Time Detection of Melatonin Using Fast-Scan Cyclic Voltammetry.
Analytic. Chem.
90
8642
8650
10.1021/acs.analchem.8b01976
Pubmed Abstract
CrossRef
Google Scholar
33
Hermans
A.
Keithley
R. B.
Kita
J. M.
Sombers
L. A.
Wightman
R. M.
2008
).
Dopamine detection with fast-scan cyclic voltammetry used with analog background subtraction.
Analytic. Chem.
80
4040
4048
10.1021/ac800108j
Pubmed Abstract
CrossRef
Google Scholar
34
Hossain
M. F.
Uddin
M. S.
Uddin
G. S.
Sumsuzzman
D. M.
Islam
M. S.
Barreto
G. E.
et al
2019
).
Melatonin in Alzheimer’s disease: a latent endogenous regulator of neurogenesis to mitigate Alzheimer’s neuropathology.
Molecular Neurobiol.
56
8255
8276
10.1007/s12035-019-01660-3
Pubmed Abstract
CrossRef
Google Scholar
35
Huang
C.-T.
Chiang
R. P.-Y.
Chen
C.-L.
Tsai
Y.-J.
2014
).
Sleep deprivation aggravates median nerve injury-induced neuropathic pain and enhances microglial activation by suppressing melatonin secretion.
Sleep
37
1513
1523
10.5665/sleep.4002
Pubmed Abstract
CrossRef
Google Scholar
36
Jackson
B. P.
Dietz
S. M.
Wightman
R. M.
1995
).
Fast-scan cyclic voltammetry of 5-hydroxytryptamine.
Analytic. Chem.
67
1115
1120
Google Scholar
37
Jan
J. E.
Espezel
H.
Appleion
R.
1994
).
The treatment of sleep disorders with melatonin.
Dev. Med. Child Neurol.
36
97
107
Google Scholar
38
Jaquins-Gerstl
A.
Michael
A. C.
2015
).
A review of the effects of FSCV and microdialysis measurements on dopamine release in the surrounding tissue.
Analyst
140
3696
3708
10.1039/c4an02065k
Pubmed Abstract
CrossRef
Google Scholar
39
Johnson
J. A.
Rodeberg
N. T.
Wightman
R. M.
2016
).
Failure of standard training sets in the analysis of fast-scan cyclic voltammetry data.
ACS Chem. Neurosci.
349
359
10.1021/acschemneuro.5b00302
Pubmed Abstract
CrossRef
Google Scholar
40
Keithley
R. B.
Takmakov
P.
Bucher
E. S.
Belle
A. M.
Owesson-White
C. A.
Park
J.
et al
2011
).
Higher Sensitivity Dopamine Measurements with Faster-Scan Cyclic Voltammetry.
Anal. Chem.
83
3563
3571
10.1021/ac200143v
Pubmed Abstract
CrossRef
Google Scholar
41
Korszun
A.
Sackett-Lundeen
L.
Papadopoulos
E.
Brucksch
C.
Masterson
L.
Engelberg
N.
et al
1999
).
Melatonin levels in women with fibromyalgia and chronic fatigue syndrome.
J. Rheumatol.
26
2675
2680
Google Scholar
42
Levent
A.
2012
).
Electrochemical determination of melatonin hormone using a boron-doped diamond electrode.
Diamond Related Mater.
21
114
119
10.1016/j.diamond.2011.10.018
CrossRef
Google Scholar
43
Luengo
E.
Buendia
I.
Fernández-Mendívil
C.
Trigo-Alonso
P.
Negredo
P.
Michalska
P.
et al
2019
).
Pharmacological doses of melatonin impede cognitive decline in tau-related Alzheimer models, once tauopathy is initiated, by restoring the autophagic flux.
J. Pineal Res.
67
e12578
10.1111/jpi.12578
Pubmed Abstract
CrossRef
Google Scholar
44
MacDonald
J. R.
1987
).
Impedence Spectroscopy–Emphasizing Solid Materials and Systems.
Hoboken, NJ
John Wiley and Sons
346
Google Scholar
45
Maeda
Y.
Okemoto
Y.
Inagaki
M.
1985
).
Electrochemical formation of graphite-sulfuric acid intercalation compounds on carbon fibers.
J. Electrochem. Soc.
132
2369
10.1149/1.2113579
CrossRef
Google Scholar
46
Maestroni
G. J.
Conti
A.
Pierpaoli
W.
1986
).
Role of the pineal gland in immunity: circadian synthesis and release of melatonin modulates the antibody response and antagonizes the immunosuppressive effect of corticosterone.
J. Neuroimmunol.
13
19
30
Google Scholar
47
Mark DeWaele
Y. O.
Park
C.
Kang
Y. M.
Shin
H.
Blaha
C. D.
Bennet
K. E.
et al
2017
).
A baseline drift detrending technique for fast scan cyclic voltammetry.
Analyst
142
4317
4321
10.1039/c7an01465a
Pubmed Abstract
CrossRef
Google Scholar
48
Mayo
J. C.
Sainz
R. M.
Tan
D.-X.
Antolín
I.
Rodríguez
C.
Reiter
R. J.
2005
).
Melatonin and Parkinson’s disease.
Endocrine
27
169
178
Google Scholar
49
Mercanzini
A.
Colin
P.
Bensadoun
J.-C.
Bertsch
A.
Renaud
P.
2009
).
In vivo electrical impedance spectroscopy of tissue reaction to microelectrode arrays.
IEEE Trans. Biomed. Eng.
56
1909
1918
10.1109/tbme.2009.2018457
Pubmed Abstract
CrossRef
Google Scholar
50
Meunier
C. J.
Denison
J. D.
McCarty
G. S.
Sombers
L. A.
2020
).
Interpreting Dynamic Interfacial Changes at Carbon Fiber Microelectrodes Using Electrochemical Impedance Spectroscopy.
Langmuir
36
4214
4223
10.1021/acs.langmuir.9b03941
Pubmed Abstract
CrossRef
Google Scholar
51
Meunier
C. J.
McCarty
G. S.
Sombers
L. A.
2019
).
Drift Subtraction for Fast-Scan Cyclic Voltammetry Using DoubleWaveform Partial-Least-Squares Regression.
Anal. Chem.
91
7319
7327
10.1021/acs.analchem.9b01083
Pubmed Abstract
CrossRef
Google Scholar
52
Meunier
C. J.
Roberts
J. G.
McCarty
G. S.
Sombers
L. A.
2017
).
Background Signal as an in Situ Predictor of Dopamine Oxidation Potential: Improving Interpretation of Fast-Scan Cyclic Voltammetry Data.
ACS Chem. Neurosci.
411
419
10.1021/acschemneuro.6b00325
Pubmed Abstract
CrossRef
Google Scholar
53
Miller
E.
Morel
A.
Saso
L.
Saluk
J.
2015
).
Melatonin redox activity. Its potential clinical applications in neurodegenerative disorders.
Curr. Topics Med. Chem.
15
163
169
10.2174/1568026615666141209160556
CrossRef
Google Scholar
54
Mukherjee
D.
Roy
S. G.
Bandyopadhyay
A.
Chattopadhyay
A.
Basu
A.
Mitra
E.
et al
2010
).
Melatonin protects against isoproterenol-induced myocardial injury in the rat: antioxidative mechanisms.
J. Pineal Res.
48
251
262
10.1111/j.1600-079x.2010.00749.x
Pubmed Abstract
CrossRef
Google Scholar
55
Neeraj Kumar
R. N. G.
2017
).
Electrochemical Behavior of Melatonin and its Sensing in Pharmaceutical Formulations and in Human Urine.
Curr. Pharm. Analysis
13
85
90
10.2174/1573412912666160422154459
CrossRef
Google Scholar
56
Nesbitt
K. M.
Varner
E. L.
Jaquins-Gerstl
A.
Michael
A. C.
2015
).
Microdialysis in the rat striatum: effects of 24 h dexamethasone retrodialysis on evoked dopamine release and penetration injury.
ACS Chem. Neurosci.
163
173
10.1021/cn500257x
Pubmed Abstract
CrossRef
Google Scholar
57
Nguyen
M. D.
Venton
B. J.
2014
).
Fast-scan Cyclic Voltammetry for the Characterization of Rapid Adenosine Release.
Comput. Struct. Biotechnol. J.
29
47
54
10.1016/j.csbj.2014.12.006
Pubmed Abstract
CrossRef
Google Scholar
58
Nimbalkar
S.
Castagnola
E.
Balasubramani
A.
Scarpellini
A.
Samejima
S.
Khorasani
A.
et al
2018
).
Ultra-capacitive carbon neural probe allows simultaneous long-term electrical stimulations and high-resolution neurotransmitter detection.
Sci. Rep.
14
Google Scholar
59
Oh
Y.
Park
C.
Kim
D. H.
Shin
H.
Kang
Y. M.
DeWaele
M.
et al
2016
).
Monitoring in vivo changes in tonic extracellular dopamine level by charge-balancing multiple waveform fast-scan cyclic voltammetry.
Analytical Chem.
88
10962
10970
10.1021/acs.analchem.6b02605
Pubmed Abstract
CrossRef
Google Scholar
60
Ou
Y.
Buchanan
A. M.
Witt
C. E.
Hashemi
P.
2019
).
Frontiers in electrochemical sensors for neurotransmitter detection: towards measuring neurotransmitters as chemical diagnostics for brain disorders.
Analytic. Methods
11
2738
2755
10.1039/c9ay00055k
Pubmed Abstract
CrossRef
Google Scholar
61
Poon
M.
McCreery
R. L.
Engstrom
R.
1988
).
Laser activation of carbon electrodes. Relationship between laser-induced surface effects and electron transfer activation.
Analytic. Chem.
60
1725
1730
10.1021/ac00168a018
CrossRef
Google Scholar
62
Puthongkham
P.
Venton
B. J.
2020
).
Recent Advances in Fast-Scan Cyclic Voltammetry.
Analyst
145
1087
1102
10.1039/c9an01925a
Pubmed Abstract
CrossRef
Google Scholar
63
Pyakurel
P.
Privman Champaloux
E.
Venton
B. J.
2016
).
Fast-scan cyclic voltammetry (FSCV) detection of endogenous octopamine in Drosophila melanogaster ventral nerve cord.
ACS Chem. Neurosci.
1112
1119
10.1021/acschemneuro.6b00070
Pubmed Abstract
CrossRef
Google Scholar
64
Reiter
R. J.
Mayo
J. C.
Tan
D. X.
Sainz
R. M.
Alatorre-Jimenez
M.
Qin
L.
2016
).
Melatonin as an antioxidant: under promises but over delivers.
J. Pineal Res.
61
253
278
10.1111/jpi.12360
Pubmed Abstract
CrossRef
Google Scholar
65
Reiter
R. J.
Tan
D.-X.
Fuentes-Broto
L.
2010
).
Melatonin: a multitasking molecule.
Prog. Brain Res.
181
127
151
10.1016/s0079-6123(08)81008-4
CrossRef
Google Scholar
66
Reiter
R. J.
Tan
D.-X.
Mayo
J. C.
Sainz
R. M.
Leon
J.
Czarnocki
Z.
2003
).
Melatonin as an antioxidant: biochemical mechanisms and pathophysiological implications in humans.
Acta Biochim. Polonica
50
1129
1146
10.18388/abp.2003_3637
CrossRef
Google Scholar
67
Robbins
E. M.
Jaquins-Gerstl
A.
Fine
D. F.
Leong
C. L.
Dixon
C. E.
Wagner
A. K.
et al
2019
).
Extended (10-Day) Real-Time Monitoring by Dexamethasone-Enhanced Microdialysis in the Injured Rat Cortex.
ACS Chem. Neurosci.
10
3521
3531
10.1021/acschemneuro.9b00145
Pubmed Abstract
CrossRef
Google Scholar
68
Roberts
J. G.
Sombers
L. A.
2018
).
Fast-scan cyclic voltammetry: chemical sensing in the brain and beyond.
Anal. Chem.
90
490
504
10.1021/acs.analchem.7b04732
Pubmed Abstract
CrossRef
Google Scholar
69
Roberts
J. G.
Toups
J. V.
Eyualem
E.
McCarty
G. S.
Sombers
L. A.
2013
).
In situ electrode calibration strategy for voltammetric measurements in vivo.
Analytic. Chem.
85
11568
11575
10.1021/ac402884n
Pubmed Abstract
CrossRef
Google Scholar
70
Robinson
D. L.
Venton
B. J.
Heien
M. L.
Wightman
R. M.
2003
).
Detecting subsecond dopamine release with fast-scan cyclic voltammetry in vivo.
Clinic. Chem.
49
1763
1773
10.1373/49.10.1763
Pubmed Abstract
CrossRef
Google Scholar
71
Rosales-Corral
S. A.
Acuña-Castroviejo
D.
Coto-Montes
A.
Boga
J. A.
Manchester
L. C.
Fuentes-Broto
L.
et al
2012
).
Alzheimer’s disease: pathological mechanisms and the beneficial role of melatonin.
J. Pineal Res.
52
167
202
10.1111/j.1600-079x.2011.00937.x
Pubmed Abstract
CrossRef
Google Scholar
72
Roseboom
P. H.
Namboodiri
M. A.
Zimonjic
D. B.
Popescu
N. C.
Rodriguez
I. R.
Gastel
J. A.
et al
1998
).
Natural melatoninknockdown’in C57BL/6J mice: rare mechanism truncates serotonin N-acetyltransferase.
Mol. Brain Res.
63
189
197
10.1016/s0169-328x(98)00273-3
CrossRef
Google Scholar
73
Salehi
B.
Sharopov
F.
Fokou
P. V. T.
Kobylinska
A.
Jonge
L. D.
Tadio
K.
et al
2019
).
Melatonin in medicinal and food plants: Occurrence, bioavailability, and health potential for humans.
Cells
681
10.3390/cells8070681
Pubmed Abstract
CrossRef
Google Scholar
74
Sugden
D.
1983
).
Psychopharmacological effects of melatonin in mouse and rat.
J. Pharmacol. Experim. Therap.
227
587
591
Google Scholar
75
Swamy
B. K.
Venton
B. J.
2007
).
Carbon nanotube-modified microelectrodes for simultaneous detection of dopamine and serotonin in vivo.
Analyst
132
876
884
10.1039/b705552h
Pubmed Abstract
CrossRef
Google Scholar
76
Szczepanik
M.
2007
).
Melatonin and its influence on immune system.
J. Physiol. Pharmacol.
58
115
124
Google Scholar
77
Takmakov
P.
Zachek
M. K.
Keithley
R. B.
Walsh
P. L.
Donley
C.
McCarty
G. S.
et al
2010
).
Carbon microelectrodes with a renewable surface.
Anal. Chem.
82
2020
2028
10.1021/ac902753x
Pubmed Abstract
CrossRef
Google Scholar
78
Taylor
I. M.
Jaquins-Gerstl
A.
Sesack
S. R.
Michael
A. C.
2012
).
Domain-dependent effects of DAT inhibition in the rat dorsal striatum.
J. Neurochem.
122
283
294
10.1111/j.1471-4159.2012.07774.x
Pubmed Abstract
CrossRef
Google Scholar
79
Taylor
I. M.
Nesbitt
K. M.
Walters
S. H.
Varner
E. L.
Shu
Z.
Bartlow
K. M.
et al
2015
).
Kinetic diversity of dopamine transmission in the dorsal striatum.
J. Neurochem.
133
522
531
10.1111/jnc.13059
Pubmed Abstract
CrossRef
Google Scholar
80
Taylor
I. M.
Patel
N. A.
Freedman
N. C.
Castagnola
E.
Cui
X. T.
2019
).
Direct in vivo electrochemical detection of resting dopamine using Poly (3, 4-ethylenedioxythiophene)/Carbon Nanotube functionalized microelectrodes.
Anal. Chem.
91
12917
12927
10.1021/acs.analchem.9b02904
Pubmed Abstract
CrossRef
Google Scholar
81
Taylor
I. M.
Robbins
E. M.
Catt
K. A.
Cody
P. A.
Happe
C. L.
Cui
X. T.
2017
).
Enhanced dopamine detection sensitivity by PEDOT/graphene oxide coating on in vivo carbon fiber electrodes.
Biosens. Bioelectron.
89
400
410
10.1016/j.bios.2016.05.084
Pubmed Abstract
CrossRef
Google Scholar
82
Túnez
I.
Montilla
P.
Del Carmen
Munoz
M.
Feijóo
M.
Salcedo
M.
2004
).
Protective effect of melatonin on 3-nitropropionic acid-induced oxidative stress in synaptosomes in an animal model of Huntington’s disease.
J. Pineal Res.
37
252
256
10.1111/j.1600-079x.2004.00163.x
Pubmed Abstract
CrossRef
Google Scholar
83
Varner
E. L.
Jaquins-Gerstl
A.
Michael
A. C.
2016
).
Enhanced intracranial microdialysis by reduction of traumatic penetration injury at the probe track.
ACS Chem. Neurosci.
728
736
10.1021/acschemneuro.5b00331
Pubmed Abstract
CrossRef
Google Scholar
84
Vasantha
V. S.
Chen
S. M.
2005
).
Effect of Reaction Conditions on Electropolymerization of Melatonin on Bare Electrodes and PEDOT-Modified Electrodes.
J. Electrochem. Soc.
152
D151
D159
Google Scholar
85
Wang
F.
Li
J.-C.
Wu
C.-F.
Yang
J.-Y.
Xu
F.
Peng
F.
2002
).
Hypnotic activity of melatonin: involvement of semicarbazide hydrochloride, blocker of synthetic enzyme for GABA.
Acta Pharmacol. Sin.
23
860
864
Google Scholar
86
Watson
C. J.
Venton
B. J.
Kennedy
R. T.
2006
).
In Vivo Measurements of Neurotransmitters by Microdialysis Sampling.
Washington, DC
ACS Publications
Google Scholar
87
Wilhelmsen
M.
Amirian
I.
Reiter
R. J.
Rosenberg
J.
Gögenur
I.
2011
).
Analgesic effects of melatonin: a review of current evidence from experimental and clinical studies.
J. Pineal Res.
51
270
277
10.1111/j.1600-079x.2011.00895.x
Pubmed Abstract
CrossRef
Google Scholar
88
Wilks
S. J.
Richner
T. J.
Brodnick
S. K.
Kipke
D. R.
Williams
J. C.
Otto
K. J.
2012
).
Voltage biasing, cyclic voltammetry, & electrical impedance spectroscopy for neural interfaces.
JoVE
60
e3566
Google Scholar
89
Williams
J. C.
Hippensteel
J. A.
Dilgen
J.
Shain
W.
Kipke
D. R.
2007
).
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants.
J. Neural Eng.
410
10.1088/1741-2560/4/4/007
CrossRef
Google Scholar
90
Wood
K. M.
Hashemi
P.
2013
).
Fast-scan cyclic voltammetry analysis of dynamic serotonin reponses to acute escitalopram.
ACS Chem. Neurosci.
715
720
10.1021/cn4000378
Pubmed Abstract
CrossRef
Google Scholar
91
Xiao-Ping
W.
Lan
Z.
Wen-Rong
L.
Duan
J.-P.
Chen
H.-Q.
Chen
G.-N.
2002
).
Study on the Electrochemical Behavior of Melatonin with an Activated Electrode.
Electroanalysis
14
1654
1660
10.1002/elan.200290007
CrossRef
Google Scholar
92
Xie
Z.
Chen
F.
Li
W. A.
Geng
X.
Li
C.
Meng
X.
et al
2017
).
A review of sleep disorders and melatonin.
Neurol. Res.
39
559
565
Google Scholar
93
Yang
H.
Peters
J. L.
Allen
C.
Chern
S.-S.
Coalson
R. D.
Michael
A. C.
2000
).
A theoretical description of microdialysis with mass transport coupled to chemical events.
Anal. Chem.
72
2042
2049
10.1021/ac991186r
Pubmed Abstract
CrossRef
Google Scholar
94
Yu
C.-X.
Zhu
C.-B.
Xu
S.-F.
Cao
X.-D.
Wu
G.-C.
2000
).
The analgesic effects of peripheral and central administration of melatonin in rats.
Eur. J. Pharmacol.
403
49
53
10.1016/s0014-2999(00)00421-0
CrossRef
Google Scholar
95
Zhang
Y.
Cook
A.
Kim
J.
Baranov
S. V.
Jiang
J.
Smith
K.
et al
2013
).
Melatonin inhibits the caspase-1/cytochrome c/caspase-3 cell death pathway, inhibits MT1 receptor loss and delays disease progression in a mouse model of amyotrophic lateral sclerosis.
Neurobiol. Dis.
55
26
35
10.1016/j.nbd.2013.03.008
Pubmed Abstract
CrossRef
Google Scholar
Summary
Keywords
fast scan cyclic voltammetry
melatonin
fouling
carbon fiber microelectrodes
brain
electrochemical impedance spectroscopy
Citation
Castagnola E, Robbins EM, Woeppel KM, McGuier M, Golabchi A, Taylor IM, Michael AC and Cui XT (2020)
Real-Time Fast Scan Cyclic Voltammetry Detection and Quantification of Exogenously Administered Melatonin in Mice Brain
Front. Bioeng. Biotechnol.
8:602216. doi:
10.3389/fbioe.2020.602216
Received
02 September 2020
Accepted
30 October 2020
Published
24 November 2020
Volume
8 - 2020
Edited by
Jian Yang, Pennsylvania State University (PSU), United States
Reviewed by
Su-youne Chang, Mayo Clinic, United States; Xuemei Wang, Southeast University, China
Updates
© 2020 Castagnola, Robbins, Woeppel, McGuier, Golabchi, Taylor, Michael and Cui.
This is an open-access article distributed under the terms of the
Creative Commons Attribution License (CC BY)
. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Xinyan Tracy Cui,
xic11@pitt.edu
This article was submitted to Biomaterials, a section of the journal Frontiers in Bioengineering and Biotechnology
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
Article metrics
View details
PDF
ReadCube
EPUB
XML
High-impact AI
AI playbook for researchers
Your step by step support for responsible and impactful AI use
Explore the guide
Outline
Figures
Cite article
Copy to clipboard
Export citation file
BibTex
EndNote
Reference Manager
Simple Text file
Share article
Email
WeChat
Share on WeChat
Scan with WeChat to share this article
Article metrics